Product |
Description |
Application |
| FSK-R7150A |
Foil: 7u / Flame
Retardant Adhesive / Tri-Way Fiberglass Scrim 8x12/100mm/Kraft: 50gsm |
Vapor barrier for duct wrap in HVAC system.
Meet the requirement of rigorous fire rating. |
| FSK-R7160A |
Foil: 7u / Flame
Retardant Adhesive / Tri-Way Fiberglass Scrim 8x12/100mm /Kraft: 60gsm |
Thicker Kraft increases
the mechanical strength of facing. Vapor barrier for duct wrap in HVAC system. Meet the
requirement of rigorous fire rating. |
| FSK-R7150B |
Foil: 7u / Flame
Retardant Adhesive / Two-Way Fiberglass Scrim 12.5x12.5mm /Kraft: 50gsm |
Vapor barrier for duct
wrap in HVAC system. Meet the requirement of rigorous fire rating. |
| FSK-R7160B |
Foil: 7u / Flame
Retardant Adhesive / Two-Way Fiberglass Scrim 12.5x12.5mm/Kraft: 60gsm |
Thicker Kraft increases
the mechanical strength of facing. Vapor barrier for duct wrap in HVAC system. Meet the
requirement of rigorous fire rating. |
| FSK-R7350B |
Foil: 7u / Flame
Retardant Adhesive / Two-Way Fiberglass Scrim 6.25x12.5mm/Kraft: 50gsm |
Closer scrim makes facing
stiff and neat. Vapor barrier for duct wrap in HVAC system. Meet the requirement of
rigorous fire rating. |
| FSK-R7360B |
Foil: 7u / Flame
Retardant Adhesive / Two-Way Fiberglass Scrim 6.25x12.5mm /Kraft: 60gsm |
Closer scrim and thicker
Kraft makes facing stiff and neat, and provides higher mechanical strength. Vapor barrier
for duct wrap in HVAC system. Meet the requirement of rigorous fire rating. |
| FSK-7150A |
Foil: 7u / Polyethylene /
Tri-Way Scrim 8x12/100mm / Kraft: 50gsm |
Economic grade foil
facing for duct wrap in HVAC system. Used for HVAC engineering that fire rating is not
rigorous. |
| FSK-7160A |
Foil: 7u / Polyethylene
/Tri-Way Scrim 8x12/100mm /Kraft: 60gsm |
Thicker Kraft raises
mechanical Economic grade foil facing for duct wrap in HVAC system. Used for HVAC
engineering that fire rating is not rigorous. |
| FSK-7150B |
Foil: 7u / Polyethylene
/Two-Way Scrim 12.5x12.5mm / Kraft: 50gsm |
Economic grade foil
facing for duct wrap in HVAC system. Used for HVAC engineering that fire rating is not
rigorous. |
| FSK-7160B |
Foil: 7u / Polyethylene
/Two-Way Scrim 12.5x12.5mm / Kraft: 60gsm |
Thicker Kraft raises
mechanical Economic grade foil facing for duct wrap in HVAC system. Used for HVAC
engineering that fire rating is not rigorous. |
| FSK-7350B |
Foil: 7u / Polyethylene /
Two-Way Scrim 6.25x12.5 /Kraft: 50gsm |
Closer scrim makes facing
stiff and neat. Economic grade foil facing for duct wrap in HVAC system. Used for HVAC
engineering that fire rating is not rigorous. |
| FSK-7360B |
Foil: 7u / Polyethylene /
Two-Way Scrim 6.25x12.5 /Kraft: 60gsm |
Closer scrim and thicker
Kraft makes facing stiff and neat. Economic grade foil facing for duct wrap in HVAC
system. Used for HVAC engineering that fire rating is not rigorous. |
| FG-701 |
Foil: 7u /Polyethylene
/Fiberglass Cloth 14x12 |
Higher tensile strength
and tear-resistance. Vapor barrier of duct wrap and duct board in HVAC system. Used for
HVAC engineering that needs higher tensile strength and fire rating is not rigorous. |
| FG-R701 |
Foil: 7u /Flame-Retardant
Adhesive /Fiberglass Cloth 14x12 |
Higher tensile strength
and tear-resistance. Vapor barrier of duct wrap and duct board in HVAC system. Used for
HVAC engineering that needs higher tensile strength and rigorous fire rating. |
| FK-750 |
Foil: 7u /Polyethylene
/Kraft: 50gsm |
Low cost vapor barrier of
duct wrap in HVAC system. Used for HVAC engineering that both fire rating and
tear-resistance are not rigorous. |
| FK-760 |
Foil: 7u /Polyethylene /
Kraft: 60gsm |
Low cost vapor barrier of
duct wrap in HVAC system but with thicker Kraft. Used for HVAC engineering that both fire
rating and tear-resistance are not rigorous. |